[CF-metadata] cell methods: interval differs from interval given by time bounds
Dear Beat
This is described in CF 7.3. The format of cell_methods is
time: maximum (interval: 1 h)
to record the original temporal resolution of the data, and the cell bounds
should indicate intervals of 3 h over which the maximum has been calculated.
Cheers
Jonathan
> I want to write 2m Maximum Temperature which is given hourly into
> cf-standard. The maximum is calculated taking the last 3 hours into
> account.
> 'cell_methods' time: 3h maximum
> is not accepted by the compliance checker - what would be the correct way?
Received on Tue Jan 17 2006 - 01:51:38 GMT