[CF-metadata] Using units with a scale factor

From: Dave Allured - NOAA Affiliate <dave.allured>
Date: Fri, 2 Nov 2018 14:39:07 -0600

Martin,

> Units of this form ["1e3 km3"] are used when the community
> requests them, usually because that is the common practice
> within their community -- they probably exist in many NetCDF
> files outside CMIP.

> Is it reasonable to refuse units which are widely used in the
> community? I think it is worth taking some time to consider
> this, and I suggest that we allow this anomalous unit for CMIP6.

A fair question. Please clarify. Are you proposing to change the
prohibition of scaled unit strings in CF section 3.1? Or do you just want
to modify one of the conformance checkers to accommodate the CMIP6 case
alone? I am opposed to the first, but the second would be okay if it was
guarded by a software switch that is not advertised for general application.

I am concerned about backpedaling on a long standing CF restriction and
precedent that I think is good as is. OTOH, if there really is wide
support for scaled unit strings, I will drop my objection.

--Dave


On Fri, Nov 2, 2018 at 3:47 AM, Martin Juckes - UKRI STFC <
martin.juckes at stfc.ac.uk> wrote:

> Dear All,
>
> "micron" (recognised by Udunits) might be a good alternative to "um".
>
> There is a typo in the last line of my message below -- question if
> whether to replace "1e6 km2" (not m2) with "Mm2",
>
> regards,
>
> Martin
>
>
> From: Juckes, Martin (STFC,RAL,RALSP)
> Sent: 02 November 2018 08:55
>
> Dear Karl, Dave,
>
> thanks, those are good suggestions.
>
> As Karl says, 1e3 km3 is not hm3 and can't be represented with prefixes
> (Udunits does accept
>
> As a compromise, I suggest the following changes for the CMIP6 data
> request:
> 1e-3 kg --> g
> 1e6 J --> MJ
>
> and retain 1e-6 m, 1e3 km3, 1e6 km2 with a comment. For the standard names
> we can just drop the scale factor as Karl suggests.
>
> The reason these are in there is because people were not aware of the
> restriction. As I noted below, the restriction is also omitted from the
> conformance document and from the compliance checker. Units of this form
> are used when the community requests them, usually because that is the
> common practice within their community -- they probably exist in many
> NetCDF files outside CMIP.
>
> I believe that the statement in the convention to the effect that
> scale_factor and add_offset attributes can be used instead is misleading.
> These factors can be used, but they only affect the internal storage of the
> data, they to not modify what the user sees -- I think the truth is that
> packing is the only application of these attributes. The units attribute
> needs to be consistent with what the user sees, and will not be affected by
> us of a scale factor. If the motivation for a particular choice of units is
> to avoid issues with numerical precision by adding an offset, this
> underlying problem can be dealt with using the offset attribute, but if the
> choice of units has different motivation these attributes don't help.
>
> This leaves us with a problem that people want to store data in units of
> "1e3 km3" and we cannot express this in CF (except by "Mm km2", which looks
> obscure to me). Is it reasonable to refuse units which are widely used in
> the community? I think it is worth taking some time to consider this, and I
> suggest that we allow this anomalous unit for CMIP6.
>
> 1e-6 m and 1e6 m2 we could use "um" and "Mm2", but I think the results
> would be unsatisfactory for the users. Although the unit micro-meter is in
> reasonably common use, the ascii representation "um" is a little obscure,
> and "Mm" also looks obscure to me. I'm happy to take other views on these.
>
> regards,
>
> Martin
>
>
> From: CF-metadata <cf-metadata-bounces at cgd.ucar.edu> on behalf of Dave
> Allured - NOAA Affiliate <dave.allured at noaa.gov>
> Sent: 01 November 2018 20:43
>
> It sounds like consistency is more important than CF perfection in a
> particular use case. In that case, I suggest continuing use of CMIP6
> prescribed unit strings for CMIP6 purposes only, and let the CMIP6
> community know of this inconsistency with CF 3.1. This will probably be
> the least confusing for all concerned. People and software that understand
> UDUNITS will understand those scaled unit strings without help from CF.
>
> --Dave
>
>
> On Thu, Nov 1, 2018 at 1:39 PM, Taylor, Karl E. <taylor13 at llnl.gov<mailto:
> taylor13 at llnl.gov>> wrote:
> Hi again,
>
> I think some groups may have already written CMIP6 fields with the
> currently specified units that violate the CF standard, but I'd rather have
> all CMIP6 datasets have comparable numeric values, so we shouldn't change
> the units themselves, just the units attribute, as suggested originally.
> This is possible, as Martin already indicated with one exception:
>
> 1e3 km3 --> hm3
>
> I think this may be incorrect. Wouldn't 1e3 km3 be interpreted as 1e3
> (km)^3 If so, then
> 1e3 km3 = (10 km)^3
>
> and there is no prefix equivalent to "10 km", so I think we're in a fix
> for this one variable.
>
> Karl
>
>
>
> On 11/1/18 11:03 AM, Dave Allured - NOAA Affiliate wrote:
> Martin, thanks for a well stated summation of this problem.
>
> My opinion is there are good reasons for prohibiting numeric scale and
> offset in the units string, as indicated in section 3.1. (Decimal prefixes
> are fine, as always.) Therefore I agree with Karl's #1 and #3, keep the
> prohibition and do not change 3.1.
>
> The CMIP6 data request itself is a problem because it actually violates CF
> 3.1. Best remedy would be to get CMIP6 authority to agree to alternate
> units that do not use numeric scale factors. I would modify Karl's #2 like
> this:
>
> 2) Replace the scaled units in the CMIP6 data request with unscaled units
> and equivalent decimal prefix (e.g., replace "1e6 J" with "MJ"). However,
> if the result is deemed not user friendly in some way, then decide on some
> user friendly unscaled units, e.g. "J", and consumers will need to re-scale
> data later, for some purposes.
>
> Does anyone know why CMIP6 requested units in violation of CF 3.1?
>
> --Dave
>
>
> On Thu, Nov 1, 2018 at 10:58 AM, Taylor, Karl E. <taylor13 at llnl.gov
> <mailto:taylor13 at llnl.gov>> wrote:
> Hi Martin,
>
> I think the main point of the relevant paragraph in section 3.1, which
> reads
>
> "The Udunits syntax that allows scale factors and offsets to be applied to
> a unit is not supported by this standard. The application of any scale
> factors or offsets to data should be indicated by the scale_factor and
> add_offset attributes. Use of these attributes for data packing, which is
> their most important application, is discussed in detail in Section 8.1,
> "Packed Data"<http://cfconventions.org/Data/cf-conventions/cf-conven
> tions-1.7/cf-conventions.html#packed-data>."
>
> is that if you want to pack the data, the proper way to do that is through
> scale_factor and add_offset, not through the scale and offset options
> allowed by udunits in the units attribute. In general I find the
> "scale_factor" and "add_offset" attributes much easier to interpret than
> the scale and offset udunits options. I would therefore:
>
> 1) continue to forbid (or strongly discourage?) use of offset and scale in
> the units attribute (and modify the conformance document to be consistent
> with this).
>
> 2) replace the scaled units in the CMIP6 data request with units that
> might be less user friendly, but include equivalent prefix (e.g., replace
> "1e6 J" with "MJ")
>
> 3) replace in the standard names table all non-conforming units with
> conforming units. I don't think the new units need to be identical to the
> old (e.g., I would replace "1e-3 kg m-2" with "kg m-2", not "g m-2").
>
> Regarding this last point, note that the so-called "Canonical units" in
> the standard names table are there to provide guidance on what the quantity
> represents (e.g., W m-2 indicates the quantity is a flux density, not a
> flux). CF does not recommend a particular unit among all equivalent (e.g.,
> "kg" might appear in the canonical units, but "g" would be just as
> acceptable).
>
> Do others have opinions about this?
>
> best regards,
> Karl
>
>
> On 10/29/18 7:45 AM, Martin Juckes - UKRI STFC wrote:
>
> Hello Karl, Alison,
>
> As part of a separate discussion on 'months since' and 'years since' in
> time units<http://mailman.cgd.ucar.edu/pipermail/cf-metadata/2018
> /020648.html><http://mailman.cgd.ucar.edu/pipermail/cf-
> metadata/2018/020648.html>, Klaus pointed out the use of numerical scale
> factors in units strings, although allowed by Udunits, is prohibited by the
> CF convention in section 3.1. I'm raising this here because there are 3
> standard names which make use of such scale factors in their canonical
> units, and a number of CMIP6 variables. The CF conformance document
> diverges from the standard and allows any string which is accepted by
> Udunits, and hence accepts such factors. The CF checker implements the
> version according to the conformance document, as does the cf-python code
> (and hence checks on the CMIP6 variables using cf-python didn't detect this
> problem).
>
>
> The CF standard names are:
>
> integral_wrt_depth_of_product_of_sea_water_density_and_salinity : 1e-3
> kg m-2
>
> ocean_salt_x_transport, ocean_salt_y_transport: 1e-3 kg s-1
>
>
> In the CMIP6 data request, we have:
>
> 1.e6 J m-1 s-1 for atmospheric energy transport (intuadse, intvadse);
>
> 1e-3 kg m-2 for integral wrt depth of density and salinity (somint);
>
> 1e-6 m s-1 for saturated hydraulic conductivity;
>
> 1e3 km3 for sea ice volumes (sivoln, sivols);
>
> 1e6 km2 for sea ice areas (siarean, siareas, siextentn, siextents);
>
>
> Should we stick to the statement in the standards document ... and bring
> the conformance document etc into line, or could the standards document be
> interpreted more loosely?
>
>
> These scale factors could be replaced by prefixes, but I think there is
> some loss of legibility in some cases:
>
> 1e-3 kg --> g
>
> 1e6 J --> MJ
>
> 1e-6 m --> um
>
> 1e3 km3 --> hm3
>
> 1e6 km2 --> Mm2
>
>
> (here "um" is a micrometer, "hm" a hectometer and "Mm" a megameter).
>
>
> regards,
>
> Martin
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://mailman.cgd.ucar.edu/pipermail/cf-metadata/attachments/20181102/9f346991/attachment-0001.html>
Received on Fri Nov 02 2018 - 14:39:07 GMT

This archive was generated by hypermail 2.3.0 : Tue Sep 13 2022 - 23:02:43 BST

⇐ ⇒